Experimental Analysis of a Small Generator set Operating on Dual Fuel Diesel-Ethanol

  • Vailatti M
  • Altafini C
  • Telli G
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

This work aims to analyze the operation of a generator set on single fuel mode with diesel oil, and on dual fuel mode using diesel–ethanol blends. The engine used to realize the experimental analysis was a diesel cycle model, single cylinder, direct injection, air refrigerated and coupled to a three-phase electric generator, whose set capacity was 8.0 kVA. The generated electric energy was dissipated in electrical resistances inside a reservoir with running water. Fuels were blended in different volumetric ratios, using a small portion of vegetable castor oil to promote the homogenization. The percentages of substitutions of diesel oil were by 10% to 50%, increasing by 10% the replacement for each sample. Also, the engine was operated with 100% substitution of diesel oil, i.e., for this condition, the samples were composed of ethanol/castor oil 90/10 (volume/volume), 80/20 and 75/25. The blends of diesel and ethanol did not obtain good performance, mainly in taxes of substitution above 40%, causing combustion failures, operational instability, and increase of fuel consumption, although it has achieved a greatly reduction on opacity percentages. The blends with 100% of substitution of diesel oil obtained good performance except to blend with 90% ethanol, where occurred combustion failures, which caused operational instability. To these conditions, the results achieved are increase of consumption by 17%, decrease of opacity by 79%, decrease of exhaust gas temperature by 3.5% and increase of engine thermal efficiency by 1.3%. At the ethanol – castor oil blends there was a decrease in the percentage of opacity by 96%, decrease of exhaust gas temperature by 17.6%, with a minimum of operational irregularities, although fuel consumption has increased by 52.4% and the engine thermal efficiency has decreased almost 1.7%. http://dx.doi.org/10.18226/23185279.v5iss1p1

Cite

CITATION STYLE

APA

Vailatti, M. A., Altafini, C. R., Telli, G. D., & Rosa, J. S. (2017). Experimental Analysis of a Small Generator set Operating on Dual Fuel Diesel-Ethanol. Scientia Cum Industria, 5(1), 1–9. https://doi.org/10.18226/23185279.v5iss1p1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free