Intrathoracic migration of a Kirschner wire

4Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Kirschner (K) wires can easily migrate, resulting in serious complications. We report a 49-year-old woman who had a rare and late complication related to the migration of K wire. It had been used for left hip replacement 8 years ago. The patient admitted to our hospital with breathing-dependent chest pain and increasing dyspnea for ∼2 h. Chest X-ray and chest computed tomographic scans revealed the presence of a metallic image of ∼5-6 cm in the right hemithorax. There was a large hemothorax but no pneumothorax. A right thoracotomy was performed and the wire was removed without complications. Surprisingly, no injury was noted to any intervening abdominal structure intra-operatively. Patients, who are treated with K wire, should be informed of the risk of wire migration and should undergo regular postoperative follow-ups including radiography.

Cite

CITATION STYLE

APA

Özarslan, F., Arlkan, O., Acat, M., Arlkan, M., & Temel, V. (2014). Intrathoracic migration of a Kirschner wire. Journal of Surgical Case Reports, 2014(1). https://doi.org/10.1093/jscr/rjt132