Evaluation of a novel technology for newborn resuscitation: A visual display of time since birth, video–audio recording, and ergonomic resuscitation equipment: A prospective observational design

1Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective Despite advancements in technologies, the quality of intrapartum care has consistently not improved. This study evaluates the potential efficacy of a novel technology for newborn resuscitation, which provides a visual display of time since birth, video–audio recording, and ergonomic resuscitation equipment, on healthcare providers’ performance during ventilation in Nepal. Method This study utilized a prospective observational design conducted over 3 years at a referral hospital in Nepal. All infants who did not cry within 30 seconds of birth were included, and their ventilation performance was assessed across two phases: SUSTAIN (baseline phase) and Pre-MALA (pilot implementation phase). Ventilation performance was measured through direct observation and video annotation, with the median time to first ventilation compared between the two phases using the Mann–Whitney U test and generalized linear mixed model regression. Results A total of 164 newborn ventilation events were observed, with 78 during the SUSTAIN phase and 86 during Pre-MALA phase. Direct observation was done in both phases, while video-recording annotation was also conducted during Pre-MALA phase. The median time to first ventilation significantly decreased from 84.3 seconds (interquartile range (IQR): 55.4–114.0) during SUSTAIN to 48.2 seconds (IQR: 33.5–85.0) during Pre-MALA (p < 0.001). The duration of suctioning before ventilation was reduced by 17.8 seconds (adjusted coefficient = −17.8; 95% CI; −23.1, −11.8) and time to first ventilation was reduced by 33 seconds (adjusted coefficient = −33.2; 95% CI; −51.1, −15.4) during Pre-MALA. Conclusion The result suggests that novel technology during resuscitation can reduce time to first ventilation and unnecessary suctioning in a clinical setting. Further large-scale evaluations are needed to fully assess the potential impact on neonatal care.

Cite

CITATION STYLE

APA

Basnet, O., Kong, S. Y. J., Myklebust, H., Pokharel, S. M., & Ashish, K. C. (2026). Evaluation of a novel technology for newborn resuscitation: A visual display of time since birth, video–audio recording, and ergonomic resuscitation equipment: A prospective observational design. Digital Health, 12. https://doi.org/10.1177/20552076261431443

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free