Normally closed microgrippers using a highly stressed diamond-like carbon and Ni bimorph structure

29Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A normally closed microgripper with a radius of curvature of 18-50 μm using a diamond-like carbon (DLC) and stress free electroplated Ni bimorph structure has been demonstrated. The large curvature in the fingers of the microgrippers is due to the high compressive stress of the DLC layer. The radius of curvature of the figures can be adjusted by the thickness ratio, and the closure of the devices can also be adjusted by varying the finger length. This device works much more efficiently than other bimorph structures due to the large difference in thermal expansion coefficients between the DLC and the Ni layers. Preliminary electrical tests have shown these microgrippers can be opened by 60°-90° at an applied power of <20 mW. © 2004 American Institute of Physics.

Cite

CITATION STYLE

APA

Luo, J. K., Flewitt, A. J., Spearing, S. M., Fleck, N. A., & Milne, W. I. (2004). Normally closed microgrippers using a highly stressed diamond-like carbon and Ni bimorph structure. Applied Physics Letters, 85(23), 5748–5750. https://doi.org/10.1063/1.1833555