temperature threshold values of bone necrosis for thermo-explantation of dental implants-A systematic review on preclinical in vivo research

50Citations
Citations of this article
70Readers
Mendeley users who have this article in their library.

Abstract

Purpose: Very high or low temperatures will lead to bone damage. The objective of this review was to analyze threshold values for thermal bone necrosis. Methods: Histological animal studies evaluating thermal effects on bone necrosis were selected via electronic and hand searches in English and German language journals until 1 November 2019. The outcome measures were temperature-exposure intervals and laser settings effecting bone damage. Furthermore, investigated parameters were the bone-to-implant contact ratios (BIC) and infrabony pockets around dental implants after thermal treatment. For quality assessment of studies, the CAMARADES study quality checklist was applied. Results: A total of 455 animals in 25 animal studies were included for data extraction after screening of 45 titles from 957 selected titles of the MEDLINE (PubMed), The Cochrane Library, Embase andWeb of Science search. The threshold values for bone necrosis ranged between 47 °C and 55 °C for 1 min. A threshold value for cryoinsult and laser treatment has not yet been defined. However, temperatures in the vicinity of 3.5 °C produce a histologically proven effect on the bone and in the surrounding tissue. At 50 °C for 1 min, BIC values significantly decreased and infrabony pockets increased. Bone quality had an influence on the outcome, as cancellous bone suffered higher bone damage from thermal treatment compared to cortical bone. Conclusion: No clear threshold value for bone necrosis is available according to the current literature for warm and cold stimuli. More in-depth and clinical studies are required to provide further insights in assessing the potential of thermal necrosis for implant removal.

Author supplied keywords

Cite

CITATION STYLE

APA

Kniha, K., Heussen, N., Weber, E., Möhlhenrich, S. C., Hölzle, F., & Modabber, A. (2020, August 1). temperature threshold values of bone necrosis for thermo-explantation of dental implants-A systematic review on preclinical in vivo research. Materials. MDPI AG. https://doi.org/10.3390/MA13163461

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free