An evaluation of the performance and optimization of a new wastewater treatment technology: the air suction flow-biofilm reactor

4Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.
Get full text

Abstract

In this laboratory study, a novel wastewater treatment technology, the air suction flow-biofilm reactor (ASF-BR) - a sequencing batch biofilm reactor technology with a passive aeration mechanism - was investigated for its efficiency in removing organic carbon, nitrogen and phosphorus, from high-strength synthetic wastewaters. A laboratory-scale ASF-BR comprising 2 reactors, 350mm in diameter and 450mm in height, was investigated over 2 studies (Studies 1 and 2) for a total of 430 days. Study 1 lasted a total of 166 days and involved a 9-step sequence alternating between aeration, anoxic treatment and settlement. The cycle time was 12.1h and the reactors were operated at a substrate loading rate of 3.60g filtered chemical oxygen demand (CODf)/m2 media/d, 0.28g filtered total nitrogen (TNf)/m2 media/d, 0.24g ammonium-nitrogen (NH4-N)/m2 media/d and 0.07g ortho-phosphate (PO4-P)/m2 media/d. The average removal rates achieved during Study 1 were 98% CODf, 88% TNf, 97% NH4-N and 35% PO4-P. During Study 2 (264 days), the unit was operated at a loading rate of 2.49g CODf/m2 media/d, 0.24g TNf/m2 media/d, 0.20g NH4-N/m2 media/d and 0.06 PO4-P/m2 media/d. The energy requirement during this study was reduced by modifying the treatment cycle in include fewer pumping cycles. Removal rates in Study 2 averaged 97% CODf, 86% TNf, 99% NH4-N and 76% PO4-P. The excess sludge production of the system was evaluated and detailed analyses of the treatment cycles were carried out. Biomass yields were estimated at 0.09g SS/g CODf, removed and 0.21g SS/g CODf, removed for Studies 1 and 2, respectively. Gene analysis showed that the use of a partial vacuum did not affect the growth of ammonia-oxidizing bacteria. The results indicate that the ASF-BR and passive aeration technologies can offer efficient alternatives to existing technologies.

Cite

CITATION STYLE

APA

Forde, P., Kennelly, C., Gerrity, S., Collins, G., & Clifford, E. (2015). An evaluation of the performance and optimization of a new wastewater treatment technology: the air suction flow-biofilm reactor. Environmental Technology (United Kingdom), 36(9), 1188–1204. https://doi.org/10.1080/09593330.2014.982724

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free