Evaluation of a novel continuous glucose measurement device in patients with diabetes mellitus across the glycemic range

11Citations
Citations of this article
47Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: This glucose clamp study assessed the performance of an electrochemical continuous glucose monitoring (CGM) system for monitoring levels of interstitial glucose. This novel system does not require use of a trocar or needle for sensor insertion. Method: Continuous glucose monitoring sensors were inserted subcutaneously into the abdominal tissue of 14 adults with type 1 or type 2 diabetes. Subjects underwent an automated glucose clamp procedure with four consecutive post-steady-state glucose plateau periods (40 min each): (a) hypoglycemic (50 mg/dl), (b) hyperglycemic (250 mg/dl), (c) second hypoglycemic (50 mg/dl), and (d) euglycemic (90 mg/dl). Plasma glucose results obtained with YSI glucose analyzers were used for sensor calibration. Accuracy was assessed retrospectively for plateau periods and transition states, when glucose levels were changing rapidly (approximately 2 mg/dl/min). Results: Mean absolute percent difference (APD) was lowest during hypoglycemic plateaus (11.68%, 14.15%) and the euglycemic-to-hypoglycemic transition (14.21%). Mean APD during the hyperglycemic plateau was 17.11%; mean APDs were 18.12% and 19.25% during the hypoglycemic-to-hyperglycemic and hyperglycemic-to-hypoglycemic transitions, respectively. Parkes (consensus) error grid analysis (EGA) and rate EGA of the plateaus and transition periods, respectively, yielded 86.8% and 68.6% accurate results (zone A) and 12.1% and 20.0% benign errors (zone B). Continuous EGA yielded 88.5%, 75.4%, and 79.3% accurate results and 8.3%, 14.3%, and 2.4% benign errors for the euglycemic, hyperglycemic, and hypoglycemic transition periods, respectively. Adverse events were mild and unlikely to be device related. Conclusion: This novel CGM system was safe and accurate across the clinically relevant glucose range. © Diabetes Technology Society.

Cite

CITATION STYLE

APA

Morrow, L., Hompesch, M., Tideman, A. M., Matson, J., Dunne, N., Pardo, S., … Simmons, D. A. (2011). Evaluation of a novel continuous glucose measurement device in patients with diabetes mellitus across the glycemic range. Journal of Diabetes Science and Technology, 5(4), 853–859. https://doi.org/10.1177/193229681100500406

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free