Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal filtering (TSENSE)

21Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To investigate the parallel acquisition technique sensitivity encoding incorporating temporal filtering (TSENSE) with three saturation-recovery (SR) prepared pulse sequences (SR turbo fast low-angle shot [SR-Turbo-FLASH], SR true fast imaging with steady precession [SR-TrueFISP], and SR-prepared segmented echo-planar-imaging [SR-segEPI]) for semiquantitative first-pass myocardial perfusion imaging. Materials and Methods: In blood- and tissue-equivalent phantoms the relationship between signal intensity (SI) and contrast-medium concentration was evaluated for the three pulse sequences. In volunteers, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normalized upslopes (NUS) were calculated from signal-time curves (STC). Moreover, artifacts, image noise, and overall image quality were qualitatively evaluated. Results: Phantom data showed a 40% increased linear range of the relation between SI and contrast-medium concentration with TSENSE. In volunteers, TSENSE introduced significantly residual artifacts and loss in SNR and CNR. No differences were found for NUS values with TSENSE. SR-TrueFISP yielded highest SNR, CNR and quality scores. However, in SR-True-FISP images, dark-banding artifacts were most pronounced. NUS values obtained with SR-TrueFISP were significantly higher and with SR-segEPI significantly lower than with SR-TurboFLASH. Conclusion: Semiquantitative myocardial perfusion imaging can significantly benefit from TSENSE due to shorter acquisition times and increased linearity of the pulse sequences. Among the three pulse sequences tested, SR-TrueFISP yielded best image quality. SR-segEPI proved to be an interesting alternative due to shorter acquisition times, higher linearity and fewer dark-banding artifacts. © 2007 Wiley-Liss, Inc.

Cite

CITATION STYLE

APA

Weber, S., Kronfeld, A., Kunz, R. P., Fiebich, M., Horstick, G., Kreitner, K. F., & Schreiber, W. G. (2007). Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal filtering (TSENSE). Journal of Magnetic Resonance Imaging, 26(3), 569–579. https://doi.org/10.1002/jmri.21047

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free