A comparison between the Disposcope endoscope and fibreoptic bronchoscope for nasotracheal intubation: A randomized controlled trial

4Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Nasotracheal intubation (NTI) is frequently performed for oral and maxillofacial surgeries. This study evaluated whether NTI is easier when guided by Disposcope endoscopy or fibreoptic bronchoscopy. Methods: Sixty patients (30 per group) requiring NTI were randomly assigned to undergo fibreoptic bronchoscopy-guided (fibreoptic group) or Disposcope endoscope-guided (Disposcope group) NTI. The NTI time, which was defined as the time from when the fibreoptic bronchoscope or aseptic suction catheter was inserted into the nasal cavity to the time at which the tracheal tube was correctly inserted through the glottis, was recorded. Epistaxis was evaluated by direct laryngoscopy five minutes after completing NTI and was scored as one of four grades according to the following modified criteria: no epistaxis, mild epistaxis, moderate epistaxis, and severe epistaxis. Results: The time to complete NTI was significantly longer in the fibreoptic group than in the Disposcope group (38.4 s vs 24.1 s; mean difference, 14.2 s; 95% confidence interval (CI), 10.4 to 18.1). Mild epistaxis was observed in 8 patients in the fibreoptic group and in 7 patients in the Disposcope group (26.7% vs 23.3%, respectively; relative risk, 1.2; 95% CI, 0.4 to 3.9), though no moderate or severe epistaxis occurred in either group. Furthermore, no obvious nasal pain was reported by any of the patients at any time point after extubation (P = 0.74). Conclusion: NTI can be completed successfully using either fibreoptic bronchoscopy or Disposcope endoscope as a guide without any severe complications. However, compared to fibreoptic bronchoscopy, Disposcope endoscope requires less execution time (the NTI time). Trial registration: This clinical research was registered at the Chinese Clinical Trial Registry (www.chictr.org.cn, ChiCTR-IPR-17011462, date of registration, May 2017).

Cite

CITATION STYLE

APA

Yu, J., Hu, R., Wu, L., Sun, P., & Zhang, Z. (2019). A comparison between the Disposcope endoscope and fibreoptic bronchoscope for nasotracheal intubation: A randomized controlled trial. BMC Anesthesiology, 19(1). https://doi.org/10.1186/s12871-019-0834-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free