Establishment of the world health organization 2 nd International Standard for factor XI, Plasma, Human

4Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

The 1 st International Standard (IS) for blood coagulation factor XI (FXI), plasma, has been successfully used for potency labeling of FXI therapeutics and for diagnosis of FXI deficiency in patients. With stocks of the 1 st IS near depletion, a replacement is required. In addition to the functional activity value, assignment of an antigen value to the 2 nd IS would allow harmonization of antigen assay methods and differentiation of patients who have low functional activity but normal antigen FXI levels from patients who have both low functional and antigen FXI levels. The aims of this study were, therefore, to assign FXI functional activity to the 2 nd IS for FXI, plasma, and to additionally assign a new analyte, FXI antigen, to the same International Standard. The candidate material was prepared from double-spun, virology negative, normal plasma, which was pooled and filled into siliconized glass ampoules and subsequently freeze-dried. Assignment of the functional activity (FXI:C) value in International Units (IUs) was performed by one-stage clotting assay by 29 laboratories, relative to the 1 st IS. The overall geometric mean (GM) was 0.71 IU/amp with extremely low inter-laboratory variability (expressed as geometric coefficient of variation) of 1.8%. The antigen value assignment was performed by 11 laboratories and was calculated relative to normal plasma pools, as is customary with new coagulation factor analytes. The amount of antigen present in 1 ml of normal plasma was taken to be 1 U. The overall GM for the antigen assays was 0.78 IU/amp with an inter-laboratory variation of 10%. The candidate (National Institute for Biological Standards and Control code, 15/180) was established by the World Health Organization (WHO) Expert Committee on Biological Standardization in 2016 as the WHO 2 nd IS for blood coagulation FXI, plasma, with a functional activity value (FXI:C) of 0.71 IU/amp and an antigen value (FXI:Ag) of 0.78 IU/amp.

Cite

CITATION STYLE

APA

Wilmot, H., Hockley, J., Rigsby, P., & Gray, E. (2017). Establishment of the world health organization 2 nd International Standard for factor XI, Plasma, Human. Frontiers in Medicine, 4(MAR). https://doi.org/10.3389/fmed.2017.00028

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free