Abstract
The application of adenosine triphosphate (ATP) bioluminescence technology as a rapid microbiological activity monitor within a potable water system has been demonstrated. ATP measurements were taken pre- and post-infrastructure improvements within a watershed and throughout two potable water systems from source to tap. A reduction in ATP, as measured by relative light units, was identified post-infrastructure improvements. Peak ATP values for the watershed were found within the reservoirs. The treated source water remained biologically stable throughout the distribution system, with peaks attributed to nitrification. A mathematical model for predicting microbial ATP using pH, temperature, and alkalinity, was developed for the watershed studied, with an adjusted R2 of 0.84 at a 95% confidence level. Overall, ATP bioluminescence technology was found to be a suitable candidate for rapid microbiological activity testing in drinking water systems; however, technological limitations remain with respect to reproducibility that should be addressed prior to full-scale implementation.
Author supplied keywords
Cite
CITATION STYLE
Rodriguez, A. B., & Duranceau, S. J. (2020). Evaluating adenosine triphosphate bioluminescence for biomonitoring in potable water systems. Journal of Water Supply: Research and Technology - AQUA, 69(7), 668–677. https://doi.org/10.2166/AQUA.2020.016