Abstract
Air pollutants generated by indoor and outdoor sources adversely affect indoor air quality in many microenvironments. Exposure to indoor air pollutants such as hazardous volatile organic compounds (VOCs), particulate matter with diameters less than 2.5 μm (PM 2.5 ) and 1 μm (PM 1 ), and oxocarbons (e.g. CO and CO 2 ) is of great concern to policy makers and environmental authorities due to their adverse impact on public health. Indoor air pollution from smoking tobacco using a waterpipe has been a worldwide public health challenge due to its toxic, carcinogenic and cardiovascular effects. This study investigates the release of PM 2.5 , PM 1 , CO 2 , CO and 72 VOCs to assess the indoor air quality during waterpipe tobacco smoking in a controlled microenvironment and a public café. Particulate matters, CO and CO 2 were measured using an OSIRIS instrument, a 3M EVM-7, and a CO 2 meter, respectively. The VOCs were sampled using pre-evacuated silicon-coated stainless-steel canisters with a 6-l capacity and analysed by an Agilent gas chromatograph with an Entech cryogen system following the US EPA Compendium Method (TO15). All measured pollutants in the controlled microenvironment showed increasing concentrations during the waterpipe smoking session with PM 2.5 , PM 1 , CO 2 and total VOC contents reaching 31.4, 26.6, 142 and 38.4%, respectively, above their respective background concentrations. CO showed a build-up rate of 0.6 mg m −3 min −1 in the controlled microenvironment, reaching 16 mg m −3 at the end of the session. In the public waterpipe café, the maximum hourly concentrations of PM 1 , PM 2.5 , CO and CO 2 reached 27 μg m −3 , 92 μg m −3 , 49.5 mg m −3 and 3244 mg m −3 , respectively. These optimum values corresponded to the number of smokers present at the café late at night. Overall, the public waterpipe café had a higher concentration of pollutants compared with the controlled microenvironment due to the number of waterpipes used in the café. These results will provide exciting insight into waterpipe emissions in real-world settings.
Author supplied keywords
Cite
CITATION STYLE
Al-Dabbous, A. N., Khan, A. R., Al-Tamimi, S. A., Shalash, M., Bajoga, A. D., & Malek, M. J. (2019). Oxides of carbon, particulate matters and volatile organic compounds impact on indoor air quality during waterpipe smoking. International Journal of Environmental Science and Technology, 16(6), 2849–2854. https://doi.org/10.1007/s13762-018-1870-0
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.