Safety of 3-month dual antiplatelet therapy after implantation of ultrathin sirolimus-eluting stents with biodegradable polymer (Orsiro): Results from the SMART-CHOICE trial

9Citations
Citations of this article
53Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND: This study sought to investigate the safety of 3-month dual antiplatelet therapy (DAPT) in patients receiving ultrathin sirolimus-eluting stents with biodegradable polymer (Orsiro). METHODS AND RESULTS: The SMART-CHOICE (Smart Angioplasty Research Team: Comparison Between P2Y12 Antagonist Monotherapy vs Dual Anti- platelet Therapy in Patients Undergoing Implantation of Coronary Drug-Eluting Stents) randomized trial compared 3-month DAPT followed by P2Y12 inhibitor monotherapy with 12-month DAPT in 2993 patients undergoing percutaneous coronary intervention. The present analysis was a prespecified subgroup analysis for patients receiving Orsiro stents. As a post hoc analysis, comparisons between Orsiro and everolimus-eluting stents were also done among patients receiving 3-month DAPT. Of 972 patients receiving Orsiro stents, 481 patients were randomly assigned to 3-month DAPT and 491 to 12-month DAPT. At 12 months, the target vessel failure, defined as a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization, occurred in 8 patients (1.7%) in the 3-month DAPT group and in 14 patients (2.9%) in the 12-month DAPT group (hazard ratio [HR], 0.58; 95% CI, 0.24-1.39; P=0.22). In whole population who were randomly assigned to receive 3-month DAPT (n=1495), there was no significant difference in the target vessel failure between the Orsiro group and the everolimus-eluting stent group (n=1014) (1.7% versus 1.8%; HR, 0.96; 95% CI, 0.41-2.22; P=0.92). CONCLUSIONS: In patients receiving Orsiro stents, clinical outcomes at 1 year were similar between the 3-month DAPT followed by P2Y12 inhibitor monotherapy and 12-month DAPT strategies. With 3-month DAPT, there was no significant difference in target vessel failure between Orsiro and everolimus-eluting stents. REGISTRATION: URL: https://www.clini caltr ials.gov; Unique identifier: NCT02079194.

Cite

CITATION STYLE

APA

Ho Yun, K., Lee, S. Y., Cho, B. R., Jang, W. J., Bin Song, Y., Oh, J. H., … Mo Yang, Y. (2021). Safety of 3-month dual antiplatelet therapy after implantation of ultrathin sirolimus-eluting stents with biodegradable polymer (Orsiro): Results from the SMART-CHOICE trial. Journal of the American Heart Association, 10(1), 1–9. https://doi.org/10.1161/JAHA.120.018366

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free