Radioembolization lung shunt estimation based on a 90Y pretreatment procedure: A phantom study

19Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Prior to 90Y radioembolization, a pretreatment procedure is performed, in which 99mTc-macroaggerated albumin (99mTc-MAA) is administered to estimate the amount of activity shunting to the lungs. A high lung shunt fraction (LSF) may impose lower prescribed treatment activity or even impede treatment. Accurate LSF measurement is therefore important, but is hampered by the use of MAA particles, which differ from 90Y microspheres. Ideally, 90Y microspheres would also be used for the pretreatment procedure, but this would require the activity to be lower than an estimated safety threshold of about 100 MBq to avoid unintended radiation damage. However, 90Y is very challenging to image, especially at low activities (<100 MBq). The purpose of this study was to evaluate the performance of three nuclear imaging techniques in estimating the LSF in a low activity 90Y pretreatment scan, using an anthropomorphic phantom: (a) positron emission tomography/computed tomography (PET/CT), (b) Bremsstrahlung single photon emission tomography/computed tomography (SPECT/CT), and (c) planar imaging. Methods: The lungs and liver of an anthropomorphic phantom were filled with 90Y chloride to acquire an LSF of 15%. Several PET/CT (Siemens Biograph mCT), Bremsstrahlung SPECT/CT (Siemens Symbia T16) and planar images (Siemens Symbia T16) were acquired at a range of 90Y activities (1586 MBq down to 25 MBq). PET images were reconstructed using a clinical protocol (attenuation correction, TOF, scatter and random correction, OP-OSEM), SPECT images were reconstructed using both a clinical protocol (attenuation correction, OSEM) and a Monte Carlo (MC)-based reconstruction method (MC-based detector, scatter, and attenuation modeling, OSEM), for planar images the geometric mean was calculated. In addition, in all cases except clinical SPECT, background correction was included. The LSF was calculated by assessing the reconstructed activity in the lungs and in the liver, as delineated on the CT images. In addition to the 15% LSF, an extra “cold” region was included to simulate an LSF of 0%. Results: PET reconstructions accurately estimated the LSF (absolute difference <2 percent point (pp)) when total activity was over 200 MBq, but greatly overestimated the LSF (up to 25pp) when activity decreased. Bremsstrahlung SPECT clinical reconstructions overestimated the LSF (up to 13pp) when activity was both high and low. Similarly, planar images overestimated the LSF (up to 23pp). MC-based SPECT reconstructions accurately estimated the LSF with an absolute difference of less than 1.3pp for activities as low as 70 MBq. Conclusions: Bremsstrahlung SPECT/CT can accurately estimate the LSF for a 90Y pretreatment procedure using a theoretically safe 90Y activity as low as 70 MBq, when reconstructed with an MC-based model.

References Powered by Scopus

Elastix: A toolbox for intensity-based medical image registration

3349Citations
N/AReaders
Get full text

Quantitative Comparison of PET and Bremsstrahlung SPECT for Imaging the In Vivo Yttrium-90 Microsphere Distribution after Liver Radioembolization

172Citations
N/AReaders
Get full text

Holmium-166 radioembolisation in patients with unresectable, chemorefractory liver metastases (HEPAR trial): A phase 1, dose-escalation study

144Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Comparison of the Biograph Vision and Biograph mCT for quantitative <sup>90</sup>Y PET/CT imaging for radioembolisation

20Citations
N/AReaders
Get full text

lung shunt and lung dose calculation methods for radioembolization treatment planning

17Citations
N/AReaders
Get full text

Lung dose measured on post-radioembolization <sup>90</sup>Y-PET/CT and incidence of radiation pneumonitis

11Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kunnen, B., van der Velden, S., Bastiaannet, R., Lam, M. G. E. H., Viergever, M. A., & de Jong, H. W. A. M. (2018). Radioembolization lung shunt estimation based on a 90Y pretreatment procedure: A phantom study. Medical Physics, 45(10), 4744–4753. https://doi.org/10.1002/mp.13168

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 12

63%

Researcher 6

32%

Lecturer / Post doc 1

5%

Readers' Discipline

Tooltip

Medicine and Dentistry 9

43%

Physics and Astronomy 6

29%

Engineering 5

24%

Computer Science 1

5%

Save time finding and organizing research with Mendeley

Sign up for free