AP1000 is a standard nuclear power plant developed by Westinghouse and its partners by using an advanced passive safety feature. Among the five principle building structures, namely the nuclear island, turbine building, annex building, diesel generator building and radwaste building, the safety of the nuclear island building is the most concerned. This paper investigates the dynamic response of the nuclear island building of the AP1000 plant subjected to safe shutdown earthquake loadings. A finite element model for the building, which is assumed to be built in a hard-rock base, is developed and its dynamic response is computed with the aid of the commercial finite element package ANSYS. The dynamic characteristics, including the natural frequencies, the vibration modes, and the time histories for displacements, velocities, and accelerations of the building are obtained for two typical safe shutdown earthquakes, El Centro and Kobe earthquakes. The dynamic behavior of the building due to the earthquakes and its safety is examined and highlighted.
CITATION STYLE
Gan, B. S., Nguyen, D. K., & Han, A. L. (2017). Dynamic Response of AP1000 Nuclear Island Due to Safe Shutdown Earthquake Loading. In MATEC Web of Conferences (Vol. 138). EDP Sciences. https://doi.org/10.1051/matecconf/201713802008
Mendeley helps you to discover research relevant for your work.