Abstract

Electromyography is a diagnostic medical procedure used to assess the state of a muscle and its related nerves. Electromyography signals are monitored to detect neuromuscular abnormalities and diseases but can also prove useful in decoding movement-related signals. This information is vital to controlling prosthetics in a more natural way. To this end, a novel analog integrated voting classifier is proposed as a hand gesture recognition system. The voting classifiers utilize 3 separate centroid-based classifiers, each one attached to a different electromyographic electrode and a voting circuit. The main building blocks of the architecture are bump and winner-take-all circuits. To confirm the proper operation of the proposed classifier, its post-layout classification results (91.2% accuracy) are compared to a software-based implementation (93.8% accuracy) of the same voting classifier. A TSMC 90 nm CMOS process in the Cadence IC Suite was used to design and simulate the following circuits and architectures.

Cite

CITATION STYLE

APA

Alimisis, V., Mouzakis, V., Gennis, G., Tsouvalas, E., Dimas, C., & Sotiriadis, P. P. (2022). A Hand Gesture Recognition Circuit Utilizing an Analog Voting Classifier. Electronics (Switzerland), 11(23). https://doi.org/10.3390/electronics11233915