Plasma generated ozone and reactive oxygen species for point of use PPE decontamination system

12Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.
Get full text

Abstract

This paper reports a plasma reactive oxygen species (ROS) method for decontamination of PPE (N95 respirators and gowns) using a surface DBD source to meet the increased need of PPE due to the COVID-19 pandemic. A system is presented consisting of a mobile trailer (35 m3) along with several Dielectric barrier discharge sources installed for generating a plasma ROS level to achieve viral decontamination. The plasma ROS treated respirators were evaluated at the CDC NPPTL, and additional PPE specimens and material functionality testing were performed at Texas A&M. The effects of decontamination on the performance of respirators were tested using a modified version of the NIOSH Standard Test Procedure TEB-APR-STP-0059 to determine particulate filtration efficiency. The treated Prestige Ameritech and BYD brand N95 respirators show filtration efficiencies greater than 95% and maintain their integrity. The overall mechanical and functionality tests for plasma ROS treated PPE show no significant variations.

Cite

CITATION STYLE

APA

Huang, M., Hasan, M. K., Rathore, K., Baky, M. A. H., Lassalle, J., Kraus, J., … Staack, D. (2022). Plasma generated ozone and reactive oxygen species for point of use PPE decontamination system. PLoS ONE, 17(2 February). https://doi.org/10.1371/journal.pone.0262818