Comparison between Multiline Transmission and Diverging Wave Imaging: Assessment of Image Quality and Motion Estimation Accuracy

8Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

High frame rate imaging is particularly important in echocardiography for better assessment of the cardiac function. Several studies showed that diverging wave imaging (DWI) and multiline transmission (MLT) are promising methods for achieving a high temporal resolution. The aim of this study was to compare MLT and compounded motion compensation (MoCo) DWI for the same transmitted power, same frame rates [image quality and speckle tracking echocardiography (STE) assessment], and same packet size [tissue Doppler imaging (TDI) assessment]. Our results on static images showed that MLT outperforms DW in terms of resolution (by 30% on average). However, in terms of contrast, MLT outperforms DW only for the depth of 11 cm (by 40% on average), the result being reversed at a depth of 4 cm (by 27% on average). In vitro results on a spinning phantom at nine different velocities showed that similar STE axial errors (up to 2.3% difference in median errors and up to 2.1% difference in the interquartile ranges) are obtained with both ultrafast methods. On the other hand, the median lateral STE estimates were up to 13% more accurate with DW than with MLT. On the contrary, the accuracy of TDI was only up to 3% better with MLT, but the achievable DW Doppler frame rate was up to 20 times higher. However, our overall results showed that the choice of one method relative to the other is therefore dependent on the application. More precisely, in terms of image quality, DW is more suitable for imaging structures at low depths, while MLT can provide an improved image quality at the focal point that can be placed at higher depths. In terms of motion estimation, DW is more suitable for color Doppler-related applications, while MLT could be used to estimate velocities along selected lines of the image.

Cite

CITATION STYLE

APA

Badescu, E., Garcia, D., Joos, P., Bernard, A., Augeul, L., Ferrera, R., … Liebgott, H. (2019). Comparison between Multiline Transmission and Diverging Wave Imaging: Assessment of Image Quality and Motion Estimation Accuracy. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 66(10), 1560–1572. https://doi.org/10.1109/TUFFC.2019.2925581

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free