Haemodynamic vector personalization of a quadripolar left ventricular lead used for cardiac resynchronization therapy: Use of surface electrocardiogram and interventricular time delays

9Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Aims The choice of left ventricular pacing configurations (LVPCs) of quadripolar leads used for cardiac resynchronization therapy (CRT) affects haemodynamic response and thus may be a tool for device optimization. The value of surface electrocardiograms and interventricular time delays (IVDs) for optimization is unknown. Methods and results Sixteen patients implanted with a CRT device with a quadripolar LV lead underwent invasive testing of LV dP/dt. QRS durations at baseline (bl) and during biventricular pacing (biv) were measured using different LVPCs (total of 141 LVPCs; 8.8 per patient). Variations in QRS duration during biv were calculated for each patient (ΔQRS) and, when compared with intrinsic QRS duration, for all LVPCs (ΔQRSLVPC). Interventricular time delays between the poles of the LV lead were obtained from intracardiac electrograms. DIVD was calculated as IVDmax 2 IVDmin. Parameters were correlated with LV dP/dt. ΔQRS and ΔQRSLVPC both significantly correlated with LV dP/dt (P < 0.01). Correlation was found for patients with ischaemic (P < 0.001) and non-ischaemic cardiomyopathy (P < 0.05), and for patients with bl QRS duration >168 ms (P < 0.001), but not <168 ms (P = ns). The LVPC with shortest QRS duration also yielded maximal LV dP/dt in 6 of 16 patients (37.5%), and was equal or better in LV dP/dt in 12 of 16 patients (75%). ΔIVD neither correlated with ΔQRS nor ΔLV dP/dt. Conclusion DQRS predicts the maximal value of vector personalization in the individual. Reductions inQRS width, but not IVDs, correlate with acute haemodynamic response. Intra individually, in 75% of patients, the LVPC with the shortest QRS duration gives equal or superior haemodynamic results when compared with the LVPC with longest QRS duration.

Cite

CITATION STYLE

APA

Trolese, L., Biermann, J., Hartmann, M., Schluermann, F., Faber, T. S., Bode, C., & Asbach, S. (2014). Haemodynamic vector personalization of a quadripolar left ventricular lead used for cardiac resynchronization therapy: Use of surface electrocardiogram and interventricular time delays. Europace, 16(10), 1476–1481. https://doi.org/10.1093/europace/euu136

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free