Abstract

Background: Bleeding complications are common in cardiac surgery. Perioperative handling of heparin and protamine may influence the haemostasis. We hypothesized that heparin and protamine dosing based on individual titration curves would improve haemostasis in comparison to standard dosing. Subjects and Methods: Sixty patients scheduled for first time elective coronary artery bypass grafting or valve surgery were included in a prospective randomized study. The patients were randomized to heparin and protamine dosing with Hepcon HMS Plus device or to standard weight and activated clotting time (ACT) based dosing. Blood samples were collected before and 10 minutes, 2 hours and 4 hours after cardiopulmonary bypass. Primary endpoint was endogenous thrombin potential in plasma 2 hours after surgery as assessed by calibrated automated thrombography. Secondary endpoints included total heparin and protamine doses, whole blood clot formation (thromboelastometry) and post-operative bleeding volume and transfusions. Heparin effect was assessed by measuring anti-Xa activity. Results: Endogenous thrombin potential and clot formation deteriorated in both groups after surgery without statistically significant intergroup difference. There were no significant differences between the groups in total heparin and protamine doses, heparin effect, or postoperative bleeding and transfusions at any time point. Significant inverse correlations between anti- Xa activity and endogenous thrombin potential were observed 10 min (r = -0.43, p = 0.001), 2 hours (r = -0.66, p<0.001) and 4 hours after surgery (r = -0.58, p<0.001). Conclusion: In conclusion, the results suggest that perioperative heparin and protamine dosing based on individual titration curves does not improve haemostasis after cardiac surgery. Postoperative thrombin generation capacity correlates to residual heparin effect.

Cite

CITATION STYLE

APA

Radulovic, V., Laffin, A., Hansson, K. M., Backlund, E., Baghaei, F., & Jeppsson, A. (2015). Heparin and protamine titration does not improve haemostasis after cardiac surgery: A prospective randomized study. PLoS ONE, 10(7). https://doi.org/10.1371/journal.pone.0130271

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free