Calibration of Horizontal Acoustic Doppler Current profilers by three dimensional CFD simulations

5Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This study presents a calibration method of horizontal acoustic Doppler current profilers (H-ADCP), based on 3D Computational Fluid Dynamics (CFD) simulations. Rigidly mounted H-ACCPs are currently used to continuously monitor water discharges. In this study three instruments were employed at separate sites in an unlined rock-blasted hydro power tunnel. The total discharge in the tunnel was predicted by fitting numerical and measured velocity profiles. The accuracy of the method was evaluated by comparing discharge predictions to results obtained by thermodynamic efficiency measurements. This study shows that 3D CFD simulations not only can be used to accurately calibrate H-ADCP, but also to assess the flow conditions at the locations of installation. An average error of 2% was obtained for the tunnel stretch that possessed the most uniform flow. However, the precision of the discharge estimates were confined by the CFD code's capability to correctly resolve the flow pattern.

Cite

CITATION STYLE

APA

Bratveit, K., & Olsen, N. R. B. (2015). Calibration of Horizontal Acoustic Doppler Current profilers by three dimensional CFD simulations. Engineering Applications of Computational Fluid Mechanics, 9(1), 41–49. https://doi.org/10.1080/19942060.2015.1004807

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free