The Validity of the 2-Point Method for Assessing the Force-Velocity Relationship of the Knee Flexors and Knee Extensors: The Relevance of Distant Force-Velocity Testing

11Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Over the past decade, force-velocity (F-v) profiling has emerged as a promising tool for assessing neuromuscular capacity to design individually tailored interventions in diverse populations. To date, a limited number of studies have addressed the optimization of the linear method for measuring F-v profiles of single-joint isokinetic movements. We aimed to simplify the measurement of knee extension (KE) and knee flexion (KF) isokinetic tasks by evaluating the most appropriate combination of two velocities (i.e., the 2-point method). Twenty-two healthy participants (11 males and 11 females) were included in the study. Isokinetic peak torque was measured at nine angular velocities (30-60-90-120-150-180-210-240-300°/s) and under isometric conditions (at 150° and 120° of KF for KE, and KF, respectively). Maximal theoretical force (F0), maximal theoretical velocity (v0), slope of the relationship (Sfv) and maximal theoretical power (Pmax) were derived from the linear F-v profiles of KE and KF and compared between the 9-point method and all possible combinations (36 in total) of the 2-point methods. The F-v profiles obtained from nine points were linear for KE (R2 = 0.95; 95% CI = 0.94–0.96) and KF (R2 = 0.93; 95% CI = 0.90–0.95), with F0 underestimating isometric force. Further analyses revealed great to excellent validity (range: ICCs = 0.89–0.99; CV = 2.54%–4.34%) and trivial systematic error (range: ES = −0.11–0.24) of the KE 2-point method when force from distant velocities (30°/s, 60°/s or 90°/s combined with 210°/s, 240°/s or 300°/s) was used. Similarly, great to excellent validity and trivial systematic error of the KF 2-point method for F0 and Pmax (range: ICC = 0.90–0.96; CV = 2.94%–6.38%; ES = −0.07–0.14) were observed when using the previously described combinations of velocities. These results suggest that practitioners should consider using more distant velocities when performing simplified isokinetic 2-point single-joint F-v profiling. Furthermore, the F-v profile has the potential to differentiate between the mechanical properties of knee extensors and flexors and could therefore serve as a potential descriptor of performance.

Cite

CITATION STYLE

APA

Sašek, M., Mirkov, D. M., Hadžić, V., & Šarabon, N. (2022). The Validity of the 2-Point Method for Assessing the Force-Velocity Relationship of the Knee Flexors and Knee Extensors: The Relevance of Distant Force-Velocity Testing. Frontiers in Physiology, 13. https://doi.org/10.3389/fphys.2022.849275

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free