Abstract
Objectives: To compare standard-resolution balanced steady-state free precession (bSSFP) cine images with cine images acquired at low resolution but reconstructed with a deep learning (DL) super-resolution algorithm. Materials and methods: Cine cardiovascular magnetic resonance (CMR) datasets (short-axis and 4-chamber views) were prospectively acquired in healthy volunteers and patients at normal (cineNR: 1.89 × 1.96 mm2, reconstructed at 1.04 × 1.04 mm2) and at a low-resolution (2.98 × 3.00 mm2, reconstructed at 1.04 × 1.04 mm2). Low-resolution images were reconstructed using compressed sensing DL denoising and resolution upscaling (cineDL). Left ventricular ejection fraction (LVEF), end-diastolic volume index (LVEDVi), and strain were assessed. Apparent signal-to-noise (aSNR) and contrast-to-noise ratios (aCNR) were calculated. Subjective image quality was assessed on a 5-point Likert scale. Student’s paired t-test, Wilcoxon matched-pairs signed-rank-test, and intraclass correlation coefficient (ICC) were used for statistical analysis. Results: Thirty participants were analyzed (37 ± 16 years; 20 healthy volunteers and 10 patients). Short-axis views whole-stack acquisition duration of cineDL was shorter than cineNR (57.5 ± 8.7 vs 98.7 ± 12.4 s; p < 0.0001). No differences were noted for: LVEF (59 ± 7 vs 59 ± 7%; ICC: 0.95 [95% confidence interval: 0.94, 0.99]; p = 0.17), LVEDVi (85.0 ± 13.5 vs 84.4 ± 13.7 mL/m2; ICC: 0.99 [0.98, 0.99]; p = 0.12), longitudinal strain (−19.5 ± 4.3 vs −19.8 ± 3.9%; ICC: 0.94 [0.88, 0.97]; p = 0.52), short-axis aSNR (81 ± 49 vs 69 ± 38; p = 0.32), aCNR (53 ± 31 vs 45 ± 27; p = 0.33), or subjective image quality (5.0 [IQR 4.9, 5.0] vs 5.0 [IQR 4.7, 5.0]; p = 0.99). Conclusion: Deep-learning reconstruction of cine images acquired at a lower spatial resolution led to a decrease in acquisition times of 42% with shorter breath-holds without affecting volumetric results or image quality. Key Points: Question Cine CMR acquisitions are time-intensive and vulnerable to artifacts. Findings Low-resolution upscaled reconstructions using DL super-resolution decreased acquisition times by 35–42% without a significant difference in volumetric results or subjective image quality. Clinical relevance DL super-resolution reconstructions of bSSFP cine images acquired at a lower spatial resolution reduce acquisition times while preserving diagnostic accuracy, improving the clinical feasibility of cine imaging by decreasing breath hold duration.
Author supplied keywords
Cite
CITATION STYLE
Kravchenko, D., Isaak, A., Mesropyan, N., Peeters, J. M., Kuetting, D., Pieper, C. C., … Luetkens, J. A. (2025). Deep learning super-resolution reconstruction for fast and high-quality cine cardiovascular magnetic resonance. European Radiology, 35(5), 2877–2887. https://doi.org/10.1007/s00330-024-11145-0
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.