New image similarity measure for bronchoscope tracking based on image registration

14Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This paper presents new image similarity measure for bronchoscope tracking based on image registration between real and virtual endoscopic images. A function for bronchoscope tracking is one of the fundamental functions in a bronchoscope navigation system. Since it is difficult to attach a positional sensor at the tip of the bronchoscope due to the space limitation, image registration between real endoscopic (RE) and virtual endoscopic (VE) images becomes a strong tool for bronchoscopic camera motion tracking. The summing-type image similarity measuring methods including mean squared error or mutual information could not properly estimate the position and orientation of the endoscope, since the outputs of these methods do not change significantly due to averaging. This paper proposes new image similarity measure that effectively uses characteristic structures observed in bronchoscopic views in similarity computation. This method divides the original image into a set of small subblocks and selects only the subblocks in which characteristic shapes are seen. Then, an image similarity value is calculated only inside the selected subblocks. We applied the proposed method to eight pairs of X-ray CT images and real bronchoscopic videos. The experimental showed much improvement in continuous tracking performance. Nearly 1000 consecutive frames were tracked correctly. © Springer-Verlag Berlin Heidelberg 2003.

References Powered by Scopus

Tracking of a bronchoscope using epipolar geometry analysis and intensity-based image registration of real and virtual endoscopic images

127Citations
N/AReaders
Get full text

Registration of real and CT-derived virtual bronchoscopic images to assist transbronchial biopsy

127Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

238Citations
N/AReaders
Get full text

Hybrid bronchoscope tracking using a magnetic tracking sensor and image registration

86Citations
N/AReaders
Get full text

Stereoscopic scene flow for robotic assisted minimally invasive surgery

53Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Deguchi, D., Mori, K., Suenaga, Y., Hasegawa, J. I., Toriwaki, J. I., Takabatake, H., & Natori, H. (2003). New image similarity measure for bronchoscope tracking based on image registration. Lecture Notes in Computer Science (Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics), 2878, 399–406. https://doi.org/10.1007/978-3-540-39899-8_50

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

60%

Professor / Associate Prof. 2

40%

Readers' Discipline

Tooltip

Computer Science 2

40%

Engineering 2

40%

Earth and Planetary Sciences 1

20%

Save time finding and organizing research with Mendeley

Sign up for free