A multicentre study of the long-term results of using a flat-back polyethylene glenoid component in shoulder replacement for primary osteoarthritis

131Citations
Citations of this article
81Readers
Mendeley users who have this article in their library.

Abstract

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening (SD) as endpoints. The Constant score was found to improve from a mean of 26.8 (SD 10.3) pre-operatively to 57.6 (SD 20.0) post-operatively (p < 0.001). Active forward flexion improved from a mean of 85.3° (SD 27.4) pre-operatively to 125° (SD 37.3) post-operatively (p < 0.001). External rotation improved from a mean of 7° (SD 6.5) pre-operatively to 30.3° (SD 21.8°) post-operatively (p < 0.001). Survivorship with revision of the glenoid component as the endpoint was 99.1% at five years, 94.5% at ten years and 79.4% at 15 years. Survivorship with radiological loosening as the endpoint was 99.1% at five years, 80.3% at ten years and 33.6% at 15 years. Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years. ©2011 British Editorial Society of Bone and Joint Surgery.

Cite

CITATION STYLE

APA

Young, A., Walch, G., Boileau, P., Favard, L., Gohlke, F., Loew, M., & Molé, D. (2011). A multicentre study of the long-term results of using a flat-back polyethylene glenoid component in shoulder replacement for primary osteoarthritis. Journal of Bone and Joint Surgery - Series B, 93 B(2), 210–216. https://doi.org/10.1302/0301-620X.93B2.25086

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free