Automated Sample Preparation Enables LC-MS/MS as a Routine Diagnostic Analysis for Serum Testosterone

5Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The advantage of LC-MS/MS for analyzing serum testosterone in female, pediatric, and hypogonadal male patient samples is well accepted (J Clin Endocrinol Metab 2010;95:4542– 8). However, many clinical laboratories still use testosterone immunoassays because of the technical challenges of LC-MS/MS (Clin Chem 2010;56:1234 – 44). Although LC-MS/MS has been shown to have better accuracy and specificity than immunoassay, better reproducibility has been more elusive because of the complexities of sample preparation (Clin Chem 2008;54:1290 –7; Rev Endocr Metab Disord 2013; 14:185–205). Methods: We evaluated replacing automated immunoassay with LC-MS/MS for all testosterone analyses at the University of California San Diego Health System Center for Advanced Laboratory Medicine. We used a novel extraction media, AC Extraction Plate™ (AC Plate), from Tecan Schweiz with automated liquid handling for LC-MS/MS sample preparation. We modified the existing vendor application and validated the method for matrix effect, recovery, precision, trueness [accuracy relative to certified reference material (CRM)], specificity, reportable range, sample stability, and correlation with other methods. Results: Method performance was excellent, with a reportable range of 4 –1560 ng/dL (0.14 –54.13 nmol/L), between-day CV <6%, mean accuracy for CRM of <4.0% bias, no interference from hemolysis, icterus, lipemia, serum separator tube gel, or common steroids/metabolites, and mean bias of 1.3% vs 4 other LC-MS/MS testosterone methods. A retrospective analysis of calibration stability suggests that sparse and/or historical calibration is feasible for routine use. Conclusions: We conclude that automated extraction with the AC Plate and a focus on robustness during method development delivered ease of use and method performance consistent with adopting LC-MS/MS for all testosterone testing.

Cite

CITATION STYLE

APA

Stone, J. A., van Staveren, D. R., & Fitzerald, R. L. (2017). Automated Sample Preparation Enables LC-MS/MS as a Routine Diagnostic Analysis for Serum Testosterone. Journal of Applied Laboratory Medicine, 2(1), 33–46. https://doi.org/10.1373/jalm.2016.022772

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free