A randomized cross-over study of auto-continuous positive airway pressure versus fixed-continuous positive airway pressure in patients with obstructive sleep apnoea

39Citations
Citations of this article
64Readers
Mendeley users who have this article in their library.

Abstract

Background and objectives: To compare the efficacy of auto-CPAP (AutoSet Spirit, ResMed) versus fixed-CPAP (S6 Elite, ResMed) in improving daytime sleepiness, health status, objective compliance and the ultimate treatment preference in patients with severe OSA. Methods: The study recruited 43 subjects aged 18-65 years with newly diagnosed severe OSA (AHI >30/h). Patients were initially treated with either auto-CPAP or fixed-CPAP for 2 months and then crossed over after a washout period of 1 week for another 2 months. Results: The study was completed by 41 patients. Results are presented as mean (SE). Use of auto-CPAP in the first and the second month was significantly higher than that of fixed-CPAP [129.7 (9.9) and 130.5 (10.7) h vs 115.2 (9.5) and 113.2 (9.4) h, P = 0.04 and 0.01], whereas mean hourly use per night was 4.3 and 4.4 h versus 3.8 and 3.7 h, respectively. The Epworth sleepiness scores improved after 1 month in both treatments (13.4 to 8.5 and 8.2, P < 0.01 for both). The Sleep apnoea quality of life index improved in the first month in both compared with baseline [4.6 (0.2) to 5.0 (0.2) for auto-CPAP and 4.9 (0.2) for fixed-CPAP, P = 0.01 and 0.04, respectively], with no difference between the two treatments. Nine and 30 patients preferred auto-CPAP and fixed-CPAP, respectively, at the end of the trial, whereas 14 and 25 patients would have chosen the same treatments if cost had not been a consideration. Conclusions: Auto-CPAP and fixed-CPAP were equally effective in improving symptoms and health status in patients with severe OSA. Usage was higher with auto-CPAP, but more patients ultimately chose fixed-CPAP. © 2007 The Authors.

Cite

CITATION STYLE

APA

To, K. W., Chan, W. C., Choo, K. L., Lam, W. K., Wong, K. K., & Hui, D. S. (2008). A randomized cross-over study of auto-continuous positive airway pressure versus fixed-continuous positive airway pressure in patients with obstructive sleep apnoea. Respirology, 13(1), 79–86. https://doi.org/10.1111/j.1440-1843.2007.01138.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free