Abstract
A high sensitivity Kerr magnetometer (ΔI/I = 1/30) is presented, making use of open source hardware and software. By making time resolved measurements (up to 0.15 s/cycle) the signal quality has been greatly improved up to an order of magnitude, enabling us to compare our measurements with commercial vibrating sample magnetometers. We also present an additional setup to amplify the Kerr signal in a 25:1 scale, cleaning a large part of the electronic and trigger noise.
Cite
CITATION STYLE
Arroyave, M. A., Marin Ramirez, J. M., Campillo, G., López, J. H., Arnache, O. L., & Osorio, J. (2019). A Kerr magnetometer setup in the kHz regime based on open-hardware architecture. In Journal of Physics: Conference Series (Vol. 1247). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/1247/1/012047