Abstract
Radiation damage to macromolecular crystals at third-generation synchrotron sites constitutes a major source of systematic error in X-ray data collection. Here, a computational method to partially correct the observed intensities during data reduction is described and investigated. The method consists of a redundancy-based zero-dose extrapolation of a decay function that is fitted to the intensities of all observations of a unique reflection as a function of dose. It is shown in a test case with weak anomalous signal that this conceptually simple correction, when applied to each unique reflection, can significantly improve the accuracy of averaged intensities and single-wavelength anomalous dispersion phases and leads to enhanced experimental electron-density maps. Limitations of and possible improvements to the method are discussed.
Cite
CITATION STYLE
Diederichs, K., McSweeney, S., & Ravelli, R. B. G. (2003). Zero-dose extrapolation as part of macromolecular synchrotron data reduction. Acta Crystallographica - Section D Biological Crystallography, 59(5), 903–909. https://doi.org/10.1107/S0907444903006516
Register to see more suggestions