Abstract
A full-scale test has been performed to determine fire performance of different ETICS systems (combustible insulation, combustible insulation with fire barrier, noncombustible insulation). Test specimens were constructed and tested according to BS 8414-1:2002, while additional measurements were also conducted to obtain valuable information for better understanding of fire performance of systems used.
Author supplied keywords
Cite
CITATION STYLE
Bjegović, D., Pečur, I. B., Milovanović, B., Rukavina, M. J., & Bagarić, M. (2016). Usporedba ponašanja različitih ETICS sustava u uvjetima požara ispitivanjem u stvarnoj veličini. Gradjevinar, 68(5), 357–369. https://doi.org/10.14256/JCE.1347.2015