Comparative accuracy of bowel ultrasound versus magnetic resonance enterography in combination with colonoscopy in assessing Crohn's disease and guiding clinical decision-making

115Citations
Citations of this article
116Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The comparative accuracy of bowel ultrasound [US] versus magnetic resonance enterography [MRE] in combination with colonoscopy [CS] in assessing Crohn's disease [CD] and influencing the decision-making process is unknown. Methods: Consecutive ileo-colonic CD patients seen in a tertiary referral centre were prospectively assessed by MRE, CS, and bowel US, within 1 week. Sensitivity, specificity, accuracy, positive predictive value [PPV], and negative predictive value [NPV] of bowel US in assessing localisation, enhancement [presence of vascularisation at Power Doppler], active disease [presence of ulcers at colonoscopy], strictures, fistulas, and abscesses were calculated using CS + MRE findings together as a reference standard.Two blinded inflammatory bowel disease [IBD] specialists reviewed MRE and bowel US findings and were asked to decide the therapeutic strategy [continue versus change therapy]. Kappa agreement with clinical decision was calculated. Results: Sixty CD patients [36 with endoscopic disease activity, 28 with complications] were enrolled. For localisation, sensitivity, specificity, accuracy, PPV, and NPV of bowel US were 88%, 96%, 91%, 96%, and 85%, respectively; for enhancement, 87%, 92%, 89%, 93%, and 86%; for activity, 92%, 100%, 96%, 100%, and 94%; for strictures, 75%, 86%, 81%, 78%, and 83%; for fistulas, 100%, 98%, 98%, 66%, and 100%; for abscesses, 100%, 96%, 96%, 33%, and 100%.The concordance of management of CD patients based on bowel US or MRE findings, alone, compared with clinical decision, was 0.768 and 0.767, respectively [p <0.001]. The concordance between bowel US and MRE on management of CD patients was 0.800 [p <0.001]. Conclusions: Bowel US is very accurate in assessing CD and is a non-invasive, easy-to-use tool to manage CD patients in clinical practice.

Cite

CITATION STYLE

APA

Allocca, M., Fiorino, G., Bonifacio, C., Furfaro, F., Gilardi, D., Argollo, M., … Danese, S. (2018). Comparative accuracy of bowel ultrasound versus magnetic resonance enterography in combination with colonoscopy in assessing Crohn’s disease and guiding clinical decision-making. Journal of Crohn’s and Colitis, 12(11), 1280–1287. https://doi.org/10.1093/ecco-jcc/jjy093

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free