Abstract

Background: Women are less likely to receive cardiac resynchronization therapy, yet, they are more responsive to the therapy and respond at shorter QRS duration. The present study hypothesized that a relatively larger left ventricular (LV) electrical dyssynchrony in smaller hearts contributes to the better cardiac resynchronization therapy response in women. For this, the vectorcardiography-derived QRS area is used, since it allows for a more detailed quantification of electrical dyssynchrony compared with conventional electrocardiographic markers. Methods: Data from a multicenter registry of 725 cardiac resynchronization therapy patients (median follow-up, 4.2 years [interquartile range, 2.7-6.1]) were analyzed. Baseline electrical dyssynchrony was evaluated using the QRS area and the corrected QRS area for heart size using the LV end-diastolic volume (QRSarea/LVEDV). Impact of the QRSarea/LVEDV ratio on the association between sex and LV reverse remodeling (LV end-systolic volume change) and sex and the composite outcome of all-cause mortality, LV assist device implantation, or heart transplantation was assessed. Results: At baseline, women (n=228) displayed larger electrical dyssynchrony than men (QRS area, 132±55 versus 123±58 μVs; P=0.043), which was even more pronounced for the QRSarea/LVEDV ratio (0.76±0.46 versus 0.57±0.34 μVs/mL; P<0.001). After multivariable analyses, female sex was associated with LV end-systolic volume change (β=0.12; P=0.003) and a lower occurrence of the composite outcome (hazard ratio, 0.59 [0.42-0.85]; P=0.004). A part of the female advantage regarding reverse remodeling was attributed to the larger QRSarea/LVEDV ratio in women (25-fold change in β from 0.12 to 0.09). The larger QRSarea/LVEDV ratio did not contribute to the better survival observed in women. In both volumetric responders and nonresponders, female sex remained strongly associated with a lower risk of the composite outcome (adjusted hazard ratio, 0.59 [0.36-0.97]; P=0.036; and 0.55 [0.33-0.90]; P=0.018, respectively). Conclusions: Greater electrical dyssynchrony in smaller hearts contributes, in part, to more reverse remodeling observed in women after cardiac resynchronization therapy, but this does not explain their better long-term outcomes.

Cite

CITATION STYLE

APA

Salden, O. A. E., Van Stipdonk, A. M. W., Den Ruijter, H. M., Cramer, M. J., Kloosterman, M., Rienstra, M., … Meine, M. (2021). Heart Size Corrected Electrical Dyssynchrony and Its Impact on Sex-Specific Response to Cardiac Resynchronization Therapy. Circulation: Arrhythmia and Electrophysiology, 14(1), E008452. https://doi.org/10.1161/CIRCEP.120.008452

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free