A comparison of para-anastomotic compliance profiles after vascular anastomosis: Nonpenetrating clips versus standard sutures

57Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Anastomotic compliance is an important predictive factor for long-term patency of small diameter vascular reconstruction. In this experimental study we compare the compliance of continuous and interrupted sutured vascular anastomoses with those using nonpenetrating clips. Methods: Both common carotid arteries in nine goats (average weight, 57 ± 5.7 kg) were transected, and end-to-end anastomoses were constructed with nonpenetrating clips or polypropylene sutures. The latter were applied with both interrupted and continuous techniques. Intraluminal pressure was measured with a Millar Mikro-tip transducer, and vessel wall motion was determined with duplex ultrasound equipped with an echo-locked wall-tracking system. Diametrical compliance was determined. Environmental scanning electron microscopy was performed on explanted anastomoses. Results: There was a reduction in anastomotic compliance and associated proximal and distal para-anastomotic hyper-compliant zones with the use of all techniques. However, compliance loss was significantly less in those anastomoses with clips and interrupted sutures when compared with continuous suture (P < .001). Furthermore, the total compliance mismatch across anastomoses with continuous sutures was significantly greater than those with clips or interrupted sutures (P < .05). The mean time for constructing clipped anastomoses was 5.7 ± 1.4 minutes, which was significantly less than either continuous (P < .0001) or interrupted sutures (P < .0001). Furthermore, environmental scanning electron microscopy demonstrated minimal intimal damage with good intimal apposition in the clip group. Conclusion: Anastomoses performed with nonpenetrating clips resulted in improved para-anastomotic compliance profiles and reduced intimai damage when compared with those with polypropylene sutures. These benefits may enhance long-term graft patency by reducing the risk of anastomotic intimal hyperplasia. (J Vasc Surg 2001;33:812-20.). © 2001 Elsevier Prt. Ltd.

Cite

CITATION STYLE

APA

Baguneid, M. S., Goldner, S., Fulford, P. E., Hamilton, G., Walker, M. G., & Seifalian, A. M. (2001). A comparison of para-anastomotic compliance profiles after vascular anastomosis: Nonpenetrating clips versus standard sutures. Journal of Vascular Surgery, 33(4), 812–820. https://doi.org/10.1067/mva.2001.112806

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free