A Digital Twin System for the Sitting-to-Standing Motion of the Knee Joint

2Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

Abstract

(1) Background: A severe decline in knee joint function significantly affects the mobility of the elderly, making it a key concern in the field of geriatric health. To alleviate the pressure on the knee joints of the elderly during daily movements such as sitting and standing, effective biomechanical solutions are required. (2) Methods: In this study, a biomechanical framework was established based on mechanical analysis to derive the transfer relationship between the ground reaction force and the knee joint moment. Experiments were designed to collect knee joint data on the elderly during the sit-to-stand process. Meanwhile, magnetic resonance imaging (MRI) images were processed through a medical imaging control system to construct a detailed digital 3D knee joint model. A finite element analysis was used to verify the model to ensure the accuracy of its structure and mechanical properties. An improved radial basis function was used to fit the pressure during the entire sit-to-stand conversion process to reduce the computational workload, with an error of less than 5%. In addition, a small-target human key point recognition network was developed to analyze the image sequences captured by the camera. The knee joint angle and the knee joint pressure distribution during the sit-to-stand conversion process were mapped to a three-dimensional interactive platform to form a digital twin system. (3) Results: The system can effectively capture the biomechanical behavior of the knee joint during movement and shows high accuracy in joint angle tracking and structure simulation. (4) Conclusions: This study provides an accurate and comprehensive method for analyzing the biomechanical characteristics of the knee joint during the movement of the elderly, laying a solid foundation for clinical rehabilitation research and the design of assistive devices in the field of rehabilitation medicine.

Cite

CITATION STYLE

APA

Liu, T., Sun, L., Sun, C., Chen, Z., Li, J., & Su, P. (2025). A Digital Twin System for the Sitting-to-Standing Motion of the Knee Joint. Electronics (Switzerland), 14(14). https://doi.org/10.3390/electronics14142867

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free