Abstract
In this paper, the performance of R600a was investigated in a household refrigerator originally designed to work with R134a using varied capillary tube length (1.0, 1.15, 1.30 and 1.45 m). The refrigerator was instrumented with four thermocouples at the inlet and outlet of the major components. Also, two pressure gauges were connected to the compressor to measure the suction and discharge of the compressor. The experimental results were used to evaluate the performance of the system. The results showed that at optimal capillary tube length the COP and cooling capacity of R600a in the system increased with 45% and 4.2% respectively and the power consumption reduced with 25% using 1.30 m varied capillary tube length compared to R134a. Conclusively, R600a can serve as a retrofit in the household refrigerator systems originally designed to work with R134a refrigerant.
Author supplied keywords
Cite
CITATION STYLE
Madyira, D. M., Marangwanda, G. T., Ekundayo, F. M., Babarinde, T. O., & Akinlabi, S. A. (2019). Investigation of Household Refrigerator System with Varied Capillary Tube Length. In Journal of Physics: Conference Series (Vol. 1378). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/1378/4/042056