The main highlight of this research work is evaluation of resonant frequency for titanium omega type coriolis mass flow sensor. Coriolis mass flow sensor is used for measuring direct mass flow in pipe useful for various industrial applications. It works on the principle of Coriolis effect. Finite Element Analysis (FEA) simulation of omega flow sensor was performed using Ansys 14.5 and Solid Edge, Pro-E was used for modelling of omega tube. Titanium was selected as omega tube material. Experimental setup was prepared for omega tube coriolis flow sensor for performing different test. Experimental setup was used for investigation of different parameters effect on CMFS and validation of simulation results.
CITATION STYLE
Patil, P. P., Kumar, A., & Ahmad, F. (2018). Omega Design and FEA Based Coriolis Mass Flow Sensor (CMFS) Analysis Using Titanium Material. In IOP Conference Series: Materials Science and Engineering (Vol. 310). Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/310/1/012005
Mendeley helps you to discover research relevant for your work.