A highly selective PVC membrane electrode for Al3+ based on salicylaldehyde salicyloyl hydrazone as a neutral carrier has been prepared and studied. The sensor exhibits a good response for Al3+ over a linear range of 9.0 × 10-6to 1.0 × 10-1 mol/L, with aNemstian slope of 20.0 ± 0.2 mV/decade and detection limit of 7.0 × 10-6 mol/L. Selectivity coefficients determined by the method of separate solution indicate high selectivity for Al3+. The response mechanism was discussed in view of UV-Vis spectroscopy technique and the A.C. impedance technique. It was used as an indicator electrode in potentiometric titration of Al3+ with EDTA and in the determination of Al3+ in real samples. The electrode has a relatively fast response time, long life time and satisfactory stability.

Cite

CITATION STYLE

APA

Liu, X. L., Yuan, R., Xu, W. J., Ma, Y. H., & Chai, Y. Q. (2011). Aluminum(III)-selective PVC membrane electrode based on salicylaldehyde salicyloyl hydrazone. Journal of the Chinese Chemical Society, 58(4), 482–487. https://doi.org/10.1002/jccs.201190010