Accuracy of aspirin prophylaxis for preeclampsia prevention documentation within a large administrative dataset

2Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Low-dose aspirin prophylaxis is recommended for women at risk of preeclampsia. Capturing aspirin prophylaxis within administrative databases can be challenging since it is an over-the-counter medication. The Better Outcome Registry and Network (BORN) database, a perinatal health registry in Ontario, Canada, includes a formal variable that captures aspirin prophylaxis for preeclampsia. This variable has not been formally validated. Objectives: To assess the accuracy of the aspirin prophylaxis variable in the BORN database against an electronic medical record (EMR). Methods: This validation study comprised 200 randomly selected women who had a livebirth at St. Michael's Hospital (SMH) in Toronto, Ontario, from January 2018 to July 2022. Recorded aspirin prophylaxis in pregnancy and maternal sociodemographic characteristics were independently extracted by two abstractors. Accuracy of aspirin prophylaxis use in the BORN database was compared to that in the SMH EMR, expressed as sensitivity, specificity, positive (PPV) and negative predictive values (NPV), Cohen's kappa (κ), and overall percent agreement, with 95% confidence intervals (CI). Sensitivity analyses were performed to account for missing or unclear aspirin prophylaxis use. Results: Among 200 women, 24 (12.0%) received aspirin prophylaxis – 12.5% within the SMH EMR and 8.0% in the BORN database. Women using aspirin were older (37.0 vs 33.0 years) and had higher median gravidity (3 vs. 2). Sensitivity and specificity of the BORN aspirin prophylaxis variable were 62.5% (95% CI 40.6, 81.2) and 100.0% (95% CI 97.3, 100.0), respectively. The corresponding positive and negative predictive values were 100.0% (95% CI 78.2, 100.0), and 93.8% (95% CI 88.6, 97.1), respectively. Cohen's κ was 0.74 (95% CI 0.58, 0.90), and overall percent agreement was 94.4% (95% CI 87.1, 100.0). Conclusions: Aspirin use within the BORN database, based on a standard variable field, appears accurate enough for the potential use in epidemiological studies of aspirin prophylaxis for preeclampsia or as a covariate in related studies.

Cite

CITATION STYLE

APA

Tailor, L. S., Fajardo, R. G., Ray, J. G., Malhamé, I., & Grandi, S. M. (2024). Accuracy of aspirin prophylaxis for preeclampsia prevention documentation within a large administrative dataset. Paediatric and Perinatal Epidemiology, 38(6), 515–520. https://doi.org/10.1111/ppe.13003

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free