An amniotic fluid index ≤ 5 cm within 7 days of delivery in the third trimester is not associated with decreasing umbilical arterial pH and base excess

11Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: To determine if an amniotic fluid index (AF1) ≤ 5.0 cm within 7 days of delivery in the third trimester is associated with decreasing umbilical arterial pH and base excess. Study Design: Case for this retrospective cohort study were all pregnancies ≥26 weeks with infact membranes and an AFI ≤ 5.0 cm within 7 days of delivery between 11/99 and 7/02. Multiple gestations, aneuploid, and anomalous fetuses were exclude. Controls with an AFI ≥ 5.0 cm within 7 days of delivery were metahed to each case within 1 week by gestational age. For a control group with a mean ± SD unbilical arterial pH of 7.26±0.07 and α = 0.05, a sample size of 100 would have a power of 99% to detect a difference with a study group whose mean was 7.20. Data were compared using paired Student's t-test, Mann-Whitney, Fisher's exact χ2 and risk ratios with 95% confidence intervals. Results: In all, 131 neonates an AFI ≤ 5.0 cm were matched to 131 controls with an AFI > 5 cm. There was no diffence in gestational age (37.6±3.0, 37.7±3.0 weeks) or birth weight (2897±810, 2762±788 g). There was no difference in umbilical artery pH (7.25±0.07, 7.26±0.07) or base excess (-3.32±2.59, -2.83±2.45 mmol/l), even in small for gestational age (SGA) infants in both groups. There was no difference in the number of SGA neonates, 5-minute Apgar <7, respiratory distress syndrome, necrotizing entercolitis, or neurologic morbidity. Linear regrission showed no correlation between AFI and either umbilical arterial pH (r = -0.00047, SE = 0.001, p = 0.63) or base excess (r = -0.00047, SE = 0.001, p = 0.63) or base excess (r = -0.29, SE = 0.037, p = 0.428). Conclusion: An AFI ≤ 5.0 cm measured within 7 days of delivery in the third trimester is not associated with decreasing umbilical arterial pH and base excess. © 2004 Nature Publishing Group All rights reserved.

Cite

CITATION STYLE

APA

Driggers, R. W., Holcroft, C. J., Blakemore, K. J., & Graham, E. M. (2004). An amniotic fluid index ≤ 5 cm within 7 days of delivery in the third trimester is not associated with decreasing umbilical arterial pH and base excess. Journal of Perinatology, 24(2), 72–76. https://doi.org/10.1038/sj.jp.7211034

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free