CMR at 3.0T in routine clinical practice - tips and tricks to optimise image quality and enhance patient flow

  • Wormleighton J
  • Parke K
  • Carlton J
  • et al.
N/ACitations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Cardiac magnetic resonance (CMR) imaging at 3.0T results in improved signal-to-noise ratio (SNR), however additional challenges arise that affect image quality. Here, we describe frequently encountered artefacts at 3.0T and how to optimise scanning techniques to provide good quality cardiac images. Methods: Glenfield Hospital (Leicester, UK) performs ∼ 2500 CMR scans annually, 700 at 3.0T. These include complex congenital and stress perfusion scans as well as a diverse portfolio of research studies. Image optimisation methods (described below) can prevent or limit general and specific artefacts seen at 3T, improving image quality and patient through-put. Results: ECG Gating: Retrospective as default. Arrhythmia detection for occasional ectopics. Prospective for frequent ectopics or atrial fibrillation, using short acquisition window. Finger-pulse oximiter when ECG fails. Real-time for poor ECG and poor breath-holding. Alter Breath-hold duration: Increasing parallel-imaging factors (up to × 4 routinely) will reduce breath-hold with minimal impact on SSFP quality. Reduce spatial resolution - small reductions in phase resolution will significantly reduce breath-hold. Increasing the echo train/segments shorten breath-hold, with slight decrease in temporal resolution. Increase the number of averages(3-5) for free-breathing cine images in sedated/deaf subjects. Utilise increased SNR to acquire 2 slices per breath-hold in good breath holders to shorten exam time. Sequence-specific cardiac shim: CMR at 3.0T requires careful, targeted shimming to significantly improve image quality for SSFP cine, T1- mapping and myocardial nulling on late gadolinium enhanced images. Off resonance artefacts: Frequently occur at 3.0T on SSFP images; adjusting the radiofrequency pulse frequency offset can shift artefacts away from the area of interest. (Figure 1). Flow artefact on SSFP images: Switching to gradient echo with no flow compensation together with tight shimming reduces the appearance of flow artefacts within vessels. (Figure 2). Perfusion imaging: Increased SNR results in improved spatial resolution for single shot acquisition. Reduce phase resolution to decrease TR and maintain single beat acquisition for high heart rates (>115bpm). T1-mapping: Ensure proper adjustment of shim and center frequency to minimize off resonance Routinely isocenter. Use large field-of-view (∼400mm) and consider motion-corrected or shortened T1-mapping sequence (ShMOLLI) if available, to minimize breathing artefacts. Conclusions: Good quality CMR images at 3.0T are achievable with adapted scanning techniques and meticulous image optimisation. This improves the diagnostic value of acquired images, minimises scanning time and therefore improves subject experience and throughput in the clinical setting. (Figure Presented).

Cite

CITATION STYLE

APA

Wormleighton, J., Parke, K., Carlton, J., Thraves, O., & McCann, G. P. (2015). CMR at 3.0T in routine clinical practice - tips and tricks to optimise image quality and enhance patient flow. Journal of Cardiovascular Magnetic Resonance, 17, T10. https://doi.org/10.1186/1532-429x-17-s1-t10

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free