Impact of the blooming artefact on dental implant dimensions in 13 cone-beam computed tomography devices

  • Wanderley V
  • de Faria Vasconcelos K
  • Leite A
  • et al.
N/ACitations
Citations of this article
29Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The purpose of this study was to objectively assess dimensional alteration (blooming artefact) on dental implant using 13 cone-beam computed tomography (CBCT) devices adjusted to device-specific scanning protocols and to assess whether subjective adjustment of brightness and contrast (B&C) could alter its visualization. An anthropomorphic phantom containing a dental implant was scanned in 13 CBCT devices adjusted to three scanning protocols: medium-FOV standard resolution, small-FOV standard resolution, and small-FOV high resolution. The diameter of the implant was measured at five levels, averaged, and compared with those from a reference standard industrial CT image. B&C adjustments were performed and measurements were repeated. The intraclass correlation coefficient assessed the reliability of the measurements and general linear mixed models were applied for multiples comparisons at a 95% confidence interval. Implant diameter obtained from small-FOV high-resolution protocols in most CBCT devices was not significantly different when compared to that from the reference (p > 0.05). For standard protocols, significant dimensional alteration of the implant ranging from 23 to 34% (0.67 to 1.02 mm) was observed in 9 CBCT devices for small-FOV scanning (p < 0.05), and in 8 CBCT devices for medium-FOV scanning, implant dimensional alteration ranged significantly from 21 to 35% (0.62 to 1.04 mm). After B&C adjustments, dimensional alteration was reduced for several of the CBCT devices tested (p < 0.05). The visualization of the implant dimensional alteration differed between CBCT devices and scanning protocols with an increase in diameter ranging from 0.27 to 1.04 mm. For most CBCT devices, B&C adjustments allowed to reduce visualization of implant blooming.

Cite

CITATION STYLE

APA

Wanderley, V. A., de Faria Vasconcelos, K., Leite, A. F., Pauwels, R., Shujaat, S., Jacobs, R., & Oliveira, M. L. (2021). Impact of the blooming artefact on dental implant dimensions in 13 cone-beam computed tomography devices. International Journal of Implant Dentistry, 7(1). https://doi.org/10.1186/s40729-021-00347-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free