Incidence of atrial flutter and atrial fibrillation in patients with implanted physiological pacemakers

4Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

Atrial flutter (AF) is a troublesome arrhythmia for patients with an implanted pacemaker. Although it has recently become possible to eliminate AF by radiofrequency catheter ablation (RF-CA), the incidence of AF before and after pacemaker implantation has not been clarified. The present study was conducted with 123 consecutive patients (69.3±11.6 (SD) years old) implanted with pacemakers, excluding patients who had chronic atrial fibrillation (AFib) when the pacemaker was implanted; 69 patients with atrioventricular (AV) block and 54 patients with sick sinus syndrome (including 29 patients with bradycardia-tachycardia syndrome). All patients were implanted with physiological pacemakers. The follow-up period was 4.7±1.9 years. In 11 of the 123 patients (8.9%), AF was observed before pacemaker implantation and the incidence was significantly higher in patients with sick sinus syndrome than in those with AV block (16.7 vs 2.9%, p<0.01). Nine of the 29 patients with bradycardia-tachycardia syndrome (31%) had AF. After physiological pacemaker implantation, AF recurred in 9 of the 11 patients, and AF was newly observed in 1 patient. Thus, 10 of the 123 patients (8.1%) had AF after physiological pacemaker implantation. Recurrence of AF was not suppressed by physiological pacing. Thirty of the 123 patients had AFib before implantation of a pacemaker and its occurrence was reduced by physiological pacing (from 24.4% to 12.2%, p<0.05). The incidence of AFib in patients with AF was significantly higher than in those without AF (90.0 vs 5.3%, p<0.001). In conclusion, the recurrence of AF is not prevented by physiological pacing and is closely related to the occurrence of AFib. RF-CA should be considered in patients who have AF before pacemaker implantation.

Cite

CITATION STYLE

APA

Ishikawa, T., Sumita, S., Kikuchi, M., Nakagawa, T., Kosuge, M., Kuji, N., … Umemura, S. (2000). Incidence of atrial flutter and atrial fibrillation in patients with implanted physiological pacemakers. Japanese Circulation Journal, 64(7), 505–509. https://doi.org/10.1253/jcj.64.505

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free