Comparison of the detection and quantification of rabies antibodies in canine sera

10Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Rabies antibodies in canine sera were detected and quantified by methods: virus neutralisation test on mice (VNT), rapid fluorescence focus inhibition test (RFFIT), and fluorescent antibody virus neutralisation (FAVN). The results of rabies antibodies levels in non-vaccinated dogs obtained by all three methods were in correlation. The comparison of rabies antibody titres determined in vaccinated dogs using VNT and FAVN methods showed 86.6% correspondence, while those obtained by RFFIT and FAVN methods corresponded in almost 95% of cases.

Cite

CITATION STYLE

APA

Ondrejková, A., Süli, J., Ondrejka, R., Beníšek, Z., Franka, R., Švrček, S., … Bugarský, A. (2002). Comparison of the detection and quantification of rabies antibodies in canine sera. Veterinarni Medicina, 47(8), 218–221. https://doi.org/10.17221/5827-VETMED