Dosimetric characteristics of a linear array of γ or β-emitting seeds in intravascular irradiation: Monte Carlo studies for the AAPM TG-43/60 formalism

12Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

In principle, the AAPM TG-43/60 formalism for intravascular brachytherapy (IVBT) dosimetry of catheter-based sources is fully valid with a single seed of cylindrical symmetry and in the region comparable to or larger than the mean-free path of emitting radiation. However, for the geometry of a linear array of seeds within the few millimeter range of interest in IVBT, the suitability of the AAPM TG-43/60 formalism has not been fully addressed yet. We have meticulously investigated the dosimetric characteristics of catheter-based γ (192Ir) and β (90Sr/Y) sources using Monte Carlo methods before applying the AAPM TG-43/60 formalism. The dosimetric perturbation due to radiation interactions with neighboring seeds is at most 2% over the entire region of interest for the 192Ir source, while it increases to about 5% for the 90Sr/Y source. As the transaxial distance (y) increases beyond 3 mm, the sum of the dose contributions from neighboring seeds exceeds the dose contribution from the center seed for both sources. However, it continues to increase with the increasing y for 192Ir but is saturated beyond y = 5 mm for 90Sr/Y. Even within a few millimeters from the seeds, the dose from the low-energy betas of 192Ir is still less than 1% of the total dose. The radial dose and anisotropy functions are reformulated in reduced cylindrical coordinate with the reference point at y = 2 mm. The dose rate constant of 192Ir and the dose rate of 90Sr/Y at the reference point showed a fairly good agreement (within ± 2%) with earlier studies and the NIST-traceable value, respectively. We conclude that the dosimetric perturbation caused by close proximity of neighboring seeds is nearly negligible so that the AAPM TG-43/60 formalism can be applied to a linear array of seeds. © 2003 American Association of Physicists in Medicine.

Cite

CITATION STYLE

APA

Ye, S. J., Parsai, E. I., & Feldmeier, J. J. (2003). Dosimetric characteristics of a linear array of γ or β-emitting seeds in intravascular irradiation: Monte Carlo studies for the AAPM TG-43/60 formalism. Medical Physics, 30(3), 403–414. https://doi.org/10.1118/1.1538229

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free