Calibration Transfer of Soil Total Carbon and Total Nitrogen between Two Different Types of Soils Based on Visible-Near-Infrared Reflectance Spectroscopy

10Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Although visible-near-infrared spectroscopy can rapidly and accurately determine soil nutrients without sample destruction, some problems remain unresolved, such as the mismatch of the established spectral model with different types of samples, limiting the wide application of this technology. Here, we took riverside and mountain soils as examples to explore the calibration transfer between two different types of soils by the WMPDS-S/B algorithm (wavelet multiscale piecewise direct standardization combined with Slope/Bias correction method) and by adding new samples. The predicted TN and TC concentrations improved significantly after being transformed. Compared with adding new samples, the WMPDS-S/B algorithm obtained more accurate results. The average relative errors dropped from 440.2% (without transformation) to approximately 6% for TN and from 342.0% to approximately 7% for TC. The maximum relative errors were reduced from 538.1% to less than 20% for TN and from 403.7% to less than 20% for TC. The RMSEP decreased from 2.42 to approximately 0.04 for TN and from 15.74 to approximately 0.4 for TC. The WMPDS-S/B algorithm had advantages in selecting fewer known samples and obtaining better prediction results. In contrast to past studies, which resolved the calibration transfer between different spectrometers and the measurement environment for the same samples, our study resolved the calibration transfer between different types of samples under the same spectrometer and the measurement environment. The former could only be used for correction among instruments, while the latter fundamentally solved the problem of model sharing across different samples.

Cite

CITATION STYLE

APA

Li, X. Y., Liu, Y., Lv, M. R., Zou, Y., & Fan, P. P. (2018). Calibration Transfer of Soil Total Carbon and Total Nitrogen between Two Different Types of Soils Based on Visible-Near-Infrared Reflectance Spectroscopy. Journal of Spectroscopy, 2018. https://doi.org/10.1155/2018/8513215

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free