The interosseous membrane in radio-ulnar dissociation

62Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

In severe forearm injuries, the diagnosis of disruption of the interosseous membrane is frequently delayed and sometimes missed, giving difficulties in the salvage of forearm stability. We studied the structure and function of the interosseous membrane in 11 cadaver preparations, using mechanical and histological analysis. Seven of the specimens tested in uniaxial tension sustained mid-substance tear of the central band of the membrane at a mean peak load of 1038 ± 308 N. The axial stiffness was 190 ± 44 N/mm with elongation to failure of 10.34 ± 2.46 mm. These results provide criteria for the evaluation of reconstructive methods. A preliminary clinical investigation of the use of ultrasound suggests that this may be of value in the screening of patients with complex fractures of the forearm, and for investigating the natural history of tears of the interosseous membrane.

Cite

CITATION STYLE

APA

Wallace, A. L., Walsh, W. R., Van Rooijen, M., Hughes, J. S., & Sonnabend, D. H. (1997). The interosseous membrane in radio-ulnar dissociation. Journal of Bone and Joint Surgery - Series B, 79(3), 422–427. https://doi.org/10.1302/0301-620X.79B3.7142