Cherenkov Radiation–Based Coincidence Time Resolution Measurements in BGO Scintillators

28Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

Bismuth germanate oxide (BGO) scintillators can be re-introduced in time-of-flight positron emission tomography (TOF-PET) by exploiting the Cherenkov luminescence emitted as a result from 511 keV interactions. Accessing the timing information from the relatively few emitted Cherenkov photons is now possible due to the recent improvements in enhanced near-ultraviolet high-density (NUV-HD) silicon photomultiplier (SiPM) technology, fast and low noise readout electronics, and the development of efficient data post-processing methods. In this work, we aim to develop a scalable detector element able to achieve excellent coincidence time resolution (CTR) required for TOF-PET using BGO scintillator elements of various lengths. The proposed detector element is optically coupled to 3.14 (Formula presented.) 3.14 mm2 NUV-sensitive SiPMs mounted on a custom design circuit board. In particular, we have evaluated the CTR performance of BGO crystal elements of dimensions 3 (Formula presented.) 3 (Formula presented.) 3 mm3, 3 (Formula presented.) 3 (Formula presented.) 5 mm3, 3 (Formula presented.) 3 (Formula presented.) 10 mm3, and 3 (Formula presented.) 3 (Formula presented.) 15 mm3, with chemically etched surfaces and wrapped in Teflon tape. To achieve excellent CTR performance, we apply state-of-the-art post-processing methods during data analysis. Best values of 156 ± 6 ps, 188 ± 5 ps, 228 ± 8 ps, and 297 ± 8 ps CTR FWHM have been achieved for the 3, 5, 10, and 15 mm length BGO crystals, respectively. These values improve to 105 ± 6 ps, 127 ± 8 ps, 133 ± 4 ps, and 189 ± 8 ps CTR FWHM, when only considering the Cherenkov component of the timing signal, which is extracted by considering the events with the fastest rise time (20% of the total data). The accurate classification of the events based on their rise time is possible; thanks to the implementation of a dual threshold approach that sets the lower threshold below one light photon equivalent level and the upper one above the signal amplitude of a single photon avalanche diode (SPAD).

Cite

CITATION STYLE

APA

Gonzalez-Montoro, A., Pourashraf, S., Cates, J. W., & Levin, C. S. (2022). Cherenkov Radiation–Based Coincidence Time Resolution Measurements in BGO Scintillators. Frontiers in Physics, 10. https://doi.org/10.3389/fphy.2022.816384

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free