Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

  • Lee H
  • Koo B
  • Choi C
  • et al.
N/ACitations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm.

Cite

CITATION STYLE

APA

Lee, H. C., Koo, B. T., Choi, C. I., Park, C. S., Kwon, J., Kim, H.-S., … Min, C. H. (2020). Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator. Journal of Radiation Protection and Research, 45(3), 117–129. https://doi.org/10.14407/jrpr.2020.45.3.117