Nonspecific reactions of a commercial enzyme-linked immunosorbent assay kit (TECRA) for detection of staphylococcal enterotoxins in foods

79Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A staphylococcal enterotoxin visual immunoassay kit (TECRA) has recently become commercially available. Since the kit is an enzyme-linked immunosorbent assay system equipped with polyvalent antisera against staphylococcal enterotoxin types A to E (SEA to SEE) and the test is simple and rapid to perform (4 h), it has been widely used for screening purposes. In this study, the sensitivity of the kit for detection of SEA, SEB, and SEC in ham, cheese, and mushrooms was similar to those of kits based on an enzyme immunoassay and reversed passive latex agglutination: 0.75 to 1.0 ng of SEA per ml, 0.5 to 0.75 ng of SEB per ml, and 1.0 to 1.25 ng of SEC per ml. However, the TECRA kit showed nonspecific reactions with food samples contaminated by microorganisms other than Staphylococcus aureus, such as Enterobacter agglomerans, Enterobacter cloacae, Proteus mirabilis, Pseudomonas aeruginosa, and Serratia marcescens. The substance contributing to the false-positive results differed from true staphylococcal enterotoxins in that it was (i) heat labile (completely inactivated by heating for 2 min at 100°C, whereas true staphylococcal enterotoxins were inactivated by about 10% with this treatment), (ii) lower in molecular weight than staphylococcal enterotoxins, and (iii) not bound to a copper chelate Sepharose gel (all of the substance remained in the unbound wash fraction, whereas staphylococcal enterotoxins were quantitatively bound to the gel). The problem of false- positive results with the TECRA kit could be resolved by heat treatment (2 min at 100°C) or by cleanup procedures involving metal chelate affinity chromatography with copper chelate Sepharose for 4 h before use of the TECRA kit.

Cite

CITATION STYLE

APA

Park, C. E., Akhtar, M., & Rayman, M. K. (1992). Nonspecific reactions of a commercial enzyme-linked immunosorbent assay kit (TECRA) for detection of staphylococcal enterotoxins in foods. Applied and Environmental Microbiology, 58(8), 2509–2512. https://doi.org/10.1128/aem.58.8.2509-2512.1992

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free