Nitrogen removal in moving-bed biofilm reactor plants at low temperatures: experiences from Norway

8Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

Abstract

Cold and diluted wastewater is a major challenge for nitrogen removal at wastewater treatment plants. The moving-bed biofilm reactor (MBBR) process has proven suitable for nitrogen removal under these conditions and several full-scale plants have been in operation for more than 20 years. These plants are still performing well, even at above design loads. Recently some of these plants have been evaluated for their low-temperature performance. In general, the results showed that temperatures down to 5 °C only had a minor impact on observed nitrification and denitrification rates. Higher dissolved oxygen concentrations can boost nitrification rates and are used as a tool to increase rates at low temperatures, thus partially compensating for the temperature effect. Post-denitrification rates were boosted by a controlled increase in carbon-to-nitrogen ratios at low temperatures. MBBR processes with combined pre- and post-denitrification are recommended for nitrogen-removal plants operating at low temperatures. Design recommendations and examples of flowsheets are given.

Cite

CITATION STYLE

APA

Rusten, B., & Ødegaard, H. (2023). Nitrogen removal in moving-bed biofilm reactor plants at low temperatures: experiences from Norway. Water Science and Technology, 87(10), 2432–2440. https://doi.org/10.2166/wst.2023.154